<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>MPC</ParameterFamily>
<Syntax>
gc portraitrotationadjustureg
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Portrait media rotation adjustment in micro-radians.  This value is used to
calibrate between landscape and portrait rotation.  We know imperically that
we need this adjustment, but we do not know why.  We suspect is has to do with
inherent differences between optical and mechanical registration.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>0 [uradians]</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
12-Jun-2001
</LastModified>
<Notes>
<DescriptionText><text>
This value is only used for portrait mode imaging.
</text></DescriptionText>
<DescriptionText><text>
This value is determined using the GC process during integration.
</text></DescriptionText>
<DescriptionText><text>
Parameters are mapped as follows:
</text></DescriptionText>
<DescriptionText><text>
UReg Narrow Device
</text></DescriptionText>
<DescriptionText><text>
------------------
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text>For Pins: 3 and 4, use Parameter PortraitRotationAdjustUReg[1]</Text></ListItem>
<ListItem><Text>For Pins: 2 and 4, use Parameter PortraitRotationAdjustUReg[2]</Text></ListItem>
<ListItem><Text>For Pins: 2 and 5, use Parameter PortraitRotationAdjustUReg[3]</Text></ListItem>
<ListItem><Text>For Pins: 1 and 2, use Parameter PortraitRotationAdjustUReg[6]</Text></ListItem>
<ListItem><Text>For Pins: 5 and 6, use Parameter PortraitRotationAdjustUReg[7]</Text></ListItem>
</UnnumberedList></DescriptionText>
<DescriptionText><text>
UReg Wide Device
</text></DescriptionText>
<DescriptionText><text>
----------------
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text>For Pins: 3 and 4, use Parameter PortraitRotationAdjustUReg[1]</Text></ListItem>
<ListItem><Text>For Pins: 2 and 4, use Parameter PortraitRotationAdjustUReg[2]</Text></ListItem>
<ListItem><Text>For Pins: 2 and 5, use Parameter PortraitRotationAdjustUReg[3]</Text></ListItem>
<ListItem><Text>For Pins: 1 and 5, use Parameter PortraitRotationAdjustUReg[4]</Text></ListItem>
<ListItem><Text>For Pins: 1 and 6, use Parameter PortraitRotationAdjustUReg[5]</Text></ListItem>
<ListItem><Text>For Pins: 1 and 2, use Parameter PortraitRotationAdjustUReg[6]</Text></ListItem>
<ListItem><Text>For Pins: 5 and 6, use Parameter PortraitRotationAdjustUReg[7]</Text></ListItem>
</UnnumberedList></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/plot_gc.xml</LinkAddress><LinkTitle>Command: plot gc</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:24:04 2008 PST
</Updated>
<Links>
</Links>
</Parameter>